Loading...
Ord 697 3/8/1926 0RDINIA1,1-CE NO.697 AN O.,,qDIjTAjiCE jU,,71EITIDI11:101 SECTIONS 4, 6, 9 and 14 OF ORDINIAI�IICE 538 , AIT ORDINANCE Mr,TITLED "AN ORDINAI,Clp, n 0.1ijilICE 01,1 EIZCTI ICAL IUaGULATING J, U THE A14D NE�R IN 'v'i1-1ICH ELECTRIC WIR24�; All�D AJ,I­'� %RAT S ri I rily 'T ,91U�LL 1313 I11T.13TALI= I1T.1 THE 0-P WICHITA FALLS ,=US , A�,D X GEr H]RA Il,,7 - ROVID- i--ROVIDI1`:G FOR THE 1: �L 1.=1 CT 10 1�1 OF SUCH WORK; P' ING FOR THE ISSUANCE OF LICENSES AND FEIERI-iITS; PROVIDING TILHI FENS TO BE CHABLGED FOR DOING SUCH WORK; PROVIDIEG FOP, IHSPI CTIOYI OF OLD HOUSE WIRING; DEFINI-11TIG TEM-.13; 1TEPEALING OhDINANXES NOS. 109 and 227 , A!"11-D ALL ORDINAIT.',CES OR PARTS OT,,.l 0y DiIyALvTCES I-ii CO-1,T,11LIC'T HERX-ITIH, AND PROVIDING PENAL- TIES." CE, 'V EiTOI'O�_2 ADOPTED BY TIES." -UHICH SAID As MR SAID BOAR-J) 01' ALDE1_111EN ON THE Jill IPIMITITH DAY OF SEP`­LEJv:B1aR, A.D . 1924. BE IT OP-0AI1,71ED by the Borald of Alderrien of the City of 'Jichitu. Falls , Te:rlas : SECTION ONE That ParagraiDh 1 , Section 4, of Ordinance No . 538 , heretofore adopted on tie l5th day of Se-ptcr�bcr,19241, is hereby amended to read as f011.0-Us : That a Board of Electrical Wor-11--ers Riaaniners be , and the same is hereby created. for the City of `�,ichita, Falls, Te:�t_-),s , to be 1:nw:rn as the "Electrical 'q'iorkers E-x-am- ininC Board, " which shall consist of five:. members ,` one member of which shall be an electrical contractor, one rrenbcr shall be. an electrician in the employ of the Electric Light Cornpany; one member shall be an archi- tect ; and one member shall be a technical man; and the City Electrical Inspector shall constitute the other member of said board. All members of said board shall be residents of the city of Wichita Falls, Texas , and shall be appointed. by the Llayor and shall serve without pay. It shall be the duty of the Electrical Workers El,-andninC- Board to examine contractors as to their abil- ity and qualifications to do electrical work in the City of Wichita Falls, Texas, and if found to be competent , to issue to said applicant a certificate stating that the applicant is qualiJ.'j.cd to do electrical work in the .k City of Wichita Falls, Texas ; providing also that said board may make its own rules governing its meetings, proceedings, etc. A technical man, as defined by this ordinance , shall mean any person who is thoroughly familiar with the theory, practice and application of electricity. SECTION TWO That Paragraph 7, o , Sect-ion 6, of Ordinance 1\1o . 538, heretofore adopted. by the Board of Aldermen of the City of Wichita Falls, Texas, on the 15th day of Sept- ember, 19234, shall be amended to read hereafter as follows: Wiring contractors must wire new buildings Y[hilc being constructed and not loom the switch legs down except by special permission of the City Electrical cal Inspector.,' No . company, or individual , firm or corporation, shall permit -pieces of wire to be left on the surface of streets or alleys or dead ends to dangle from poles or buildings, or in any manner leave old or new wire in a condition that is dangerous to lif*e or property. SECTION TEME That Section 9 of Ordinance 538, heretofore adopted by the Board of Aldermen o-f the City of Wichita Falls, Texas, on the l5th day of ~eptember, 1924, be amended so as to hereafter read as follows : 1. Wiring for light , heat or power in all buildings hereafter erected, a.nd all additions to ex- isting buildings in the fire limits of the City of Wichita Falls, Texas , shall be installed in a rigid iron conduit or metal moulding systera. All buildings hereafter er- ected. for mercantile purposes, churches , schools, rooming- houses, garages, hotels„ hospitals , all apartment houses which shall consist of more than two apartments, factories, grain elevators, filling stations , refineries, and all buildi.n,r�,s to be used for public entertL:.inment within the cites- limits of the City of Ylichita Falls, shall have all vriring for light, heat and. power installed in a complete conduit or metal moulding system. All changes or addit- ions to hiring used for light , heat or pourer within the fire limilits of the City of Wichita Falls, shall be in 41 conduit or metal moulding. 2. All poorer wiring shall include all necess- ary wiring for electric motors , rectifiers, generators , electric heating and all electrical apparatus otlier than lighting and signaling equipment , and shall be in rigid iron conduit . All switches controlling motors or lights other than those mounted on switchboards shall be what is knovm as safety type externally operated indicating the on or off position. 3. Armored B X Cable will be permissible on new work only on installing door switches and window lighting where rigid iron conduit can not be used and will be permitted on old residences or where conduit is impractical , and it must not be used in cement , plaster or brick walls, or where exposed to noisture . 4. Metal mouldin can only be used on ex- posed work in compliance with the National Code of Fire Underwriters' Rules 5. Bell ringing transformers must be placed in approved metal cabinet boxes , and fused not to exceed three amperes . This shall mean that transformers may be installed in distribution cabinets if desired. a 6. All current consuming openings installed on main ceiling of store buildings for general il_iunin- ation shall be made of 600 watt capacity-, including cei ings of rooris used for mercantile Purposes, also includ- ing ceiling above and below mezzanine floors and balcon- ies , ceiling of room-- to be used for shov; rooms or dis- play roods,' of garages and in no case vii'I-l more than tyro such o- t, except in openings be permitted on one circuit, cases of decoratingp or outline, lightinLr where more than two openings to the circuit may be permitted by special permission. 7 . All conduits must be secured to boxes , junction boxes or cabinets by placing approved lock nuts on outside of box and loc,c- nuts and bushings inside of boxes. 8. All bath room,kitchen,beasement and pri- vate garage lights must be ceiling fixtures and control- led by N-,rall switches. All kitchen , bathroom, basement and private garage bracket fixtures, must be of non- conducting material and be controlled by wall switches or use of grounded fixtures at direction of Inspector. This section does not include living rooms over or in private garages , excepting that rules applying to bath rooms and -private kitchens shall apply. 9. All installations of more than four cir- cuits must have three wire service where posz;ible and residence type panel board, and all installations of eleven circuits or more , must have standard panel boards enclosed in standard approved steel cabinets. No serv- ice wires smaller than No . 10B and S. Guage will be allowed. All service wires must be installed in conduit or metal moulding from entrance intD cabinet , and also f'ron, cabi- net to first light opening. Where it is necessary to install sink;-feeders from main cabinet to distributing panels only one pair of sub-f'eed.ers will be permitted in a any one pipe. Exit lights will. be required in all apart- ments and hotel buildings more than two stories hiLh,and must be connected to house meter. 10 . All lights indicating fire escape exits shall have red lights with the words "Fire Escape Exit" clearly lettered. 11. All conduits installed in underground worT:, ice boxes and refrigirating plants must be in rigid C__ galvanized iron pipe and lead covered -aire pulled in. 12 . All o-eiling outlet boxes must be equip- ped with standard fixture studs. Fixture studs must be securely fastened with stove bolts and not less than four bolts to the stud will be accepted or an approved boltless stud. 13. Ground conductors must be grounded on the house side of meters to a good ground. (Plumbing tD vent pipes and gas pipes will not be considered as grounds . ) 14. For thirty ampere service two wires , one and t,-io circuit , a universal meter trii-ii safety switch must be used. 15 . The brand circuit fuse is accessible to the person or persons occupying the premises, where a switch i :3 located. The main fuse is sealed in such a man- ner that it can only be opened by a licensed electrician or the electric company servinE-. the City of ',i'Vichita Falls with electricity. 16. Any licensed electrician upon application to the City Electrician may obtain a permit to break a seal to the main service switch for the purpose of replacinj,7 a fuse;after lie has broken the seal for the 'Our-pose of re- placina the fuse , he must report such breaking p r om. -p t ly in writing to the electric company serving the citizens of Wichita Falls with electricity, stating that he has broken such seal and upon his failure to make such report his per- mit may. be revoked by the Board of Aldermen. For the purpose of comparison, the follo-vaing catalog numbers of four manufacturers are ,-iven, but any safety type approved universal meter trim switch that meets these requirmments , and is approved by the National Board of Fire Underwriters , will be acceptable : Square D Johns Pratt Trumbull 'lie st inEhou se 32211 971 .123 971.123 K 57924 3 wire three and four circuit 30 amp-service Square D Johns Pratt Trumbull Westinghouse 34311 975333 975333 K 57928 2 wire three and four circuit 34211 972123 972123 K 57925 for 60 amp service 27312 925336 16336 K 59462 SECTIO-11 r,'OU--q BE, IIP RMTHETi 010AINEED by the Board of Aldery.,aen of the City of 'W-Lchita Falls,Te:,.as : That tables Hos . 5 , 6, 7 and 8 of' Section 141 of Ordinance 538 , heretofore adopted by said Board on 'the 14th day of Se.pter-,fber, 1924, shall have the followinf.,, rule for determininE the sire of feeder; for more than one motor , to-wit Tal:e the maximum startin� fuse for the largest morot and the rnal—limum runninE fuse of all rotors and, this total amiperaLe i,� the size o--,;' conductors necessary to be used, except motoro of automatic st1.rtin1',,- , then the t,-.,ires rust 'L-,,e of the. combined amperage of the r.wxir.num, startin _ fuse of all raotors autoriy-,,tically started . BE IT 114URTHIM 01',I)AINIED by the Board of Aldermen of the City of Wichita Falls: That the Electric-al Inspector is he-ein y re-inspect given F- authorit to inspect and re-inect all old house elect- - rical wirinE and when said electrical is found to be in a condition danL-er,)us to 'Life 0:(- :)ro-oerty, he shall notify the ocner the--,-,eof at once to repl ace all electrical viirin,- in a sai.e condition and at the same time, have all current cut off until same is repaired and placed in a safe condition. By the term "old house elcctric.-,..l -wiring' is meant : Any house , tavern or inn iihich has been aired c.-ith electrical vii,-iw,-- for one or ore years. BE IT 1URTIM11 ORDAIN= by the A,o �'Board I d e ri.i e n - of the City of Alichitea Falls, Te-,,-,-.s, that no other -,.)rovision of th,.- Ordinance he-2eby amended shall be chanCed or affected in any manner. PASSED AND ARI)R(WED,thi s the day of 'a , A.1)-1942'6 Mayot ATTE�;T :