Loading...
Ord 1760 6/11/19567 �f7 ORDINANCE NUMBER AN ORDINANCE AMENDING SECTION V, ARTICLE 10, PARAGRAPH (a) ; AMENDING SECTION X I I ', ARTICLE 10; PARA- GRAPH (a); AND AMENDING SECTION XIX, ARTICLE 45, OF ORDINANCE NUMBER 1688, SO THAT SAID SECTIONS S .LL• j HEREAFTER READ :,S HEREIN SET OUT. BE IT ORDAINED BY THE BOARD OF ALDERMEN OF THE Cl OF WICHITA FALLS: SECTION I. That Section V of Article 10, Paragraph (a) of Ord nance No, 1688 is hereby amended by adding to para- graph (a), the following sentence: (a),..,, No pressure test will be required on lawn sprinkler system beyond the master shut -off for each sprinklered area. SECTION II. That Section XII of ;article 10, Paragraph (a) of or din Number 1688 is hereby amended so that the same shall hereafter read as follows: (a) Every sprinkler system shall be provided with a master shut -gff valve to control the entire sprinkler sys- tem and a 45 seat swing check valve shall be installed immediately ahead of the master shut -off. Each system, or part thereof, shall be provided with a means of drain- age and a back -flow preventor, or preventors, shall be installed not less than 6 inches above the grade in a protected area. In no case shall a check valve be in- stalled so as to cause a closed system in the house piping. New galvanized steel, copper, plastic, or rubber piping may be used for sprinkler systems beyond the back -flow preventor. All steel, copper and plastic piping shall be buried not less than 12 inches under- ground. Rubber sprinkler piping may be buried 6 inches underground SECTION III. That Section XIX, Article 45, of Ordinance Number 1688 is hereby amended so that the same shall hereafter read' as follows: (a) The minimum size and maximum length of piping for small heaters and appliances in dwellings and similar oc- cupancies shall be determined by the following table: r: Maximum length of D4 am F'not T)iamPfPr nf' Fine in Inches 1/2 3 4 1 Number of Outlets 10 1 2 4 14 16 20 2 4 12 14 30 1 3 10 14 40 2 9 12 50 2 8 11 60 2 7 10 70 - -- - 60 7 10 90 7 1a 100 7 '10 In addition to the above, the minimum pipe sizes for certain gas fired .appliances shall be as follows: Kitchen Range, 3/4 inch Room or Space Heater, 1/2 inch Circulating Water Heater, .L%2 inch Instantaneous Water Heater, 3/4 inch. PASSED AND APPROVED this 11th day of June, A. D. 1956. Mayor er Prepared by: City Attorney - 2 - In addition to the above, the minimum pipe sizes for certain gas fired .appliances shall be as follows: Kitchen Range, 3/4 inch Room or Space Heater, 1/2 inch Circulating Water Heater, .L%2 inch Instantaneous Water Heater, 3/4 inch. PASSED AND APPROVED this 11th day of June, A. D. 1956. Mayor er Prepared by: City Attorney - 2 -