Loading...
Ord 002-82 1/5/1982 • ORDINANCE NO. —42J AN ORDINANCE AMENDING THE PLUMBING CODE OF THE CITY OF WICHITA FALLS, TEXAS, PROVIDING FOR THE MATERIALS, SIZES, INSTALLATION AND SUPPORT USED IN CONSTRUCTING UNDERGROUND GAS SERVICE LINES FROM THE GAS MAIN TO THE GAS METER, PROVIDING FOR THE MATERIALS, SIZES AND INSTALLATION OF UNDERGROUND GAS PIPING FROM THE GAS METER TO THE BUILDING, REQUIR- ING GAS PIPE WELDING BE PERFORMED ONLY BY CERTIFIED WELDERS, PROVID- ING FOR THE METHODS OF JOINTING POLYETHYLENE PIPE AND DECLARING AMENDMENTS TO BE EMERGENCY MEAS- URES EFFECTIVE UPON PASSAGE. BE IT ORDAINED BY THE BOARD OF ALDERMEN OF THE CITY OF WICHITA FALLS, TEXAS, THAT: Section 1. Subsection (1602 . 2 . 1) Underground service lines; materials and size; is hereby amended to read as follows: " (1602 . 2 . 1) Underground service lines; materials, size, installation and support. Underground gas service lines from the gas main to the gas meter larger than two (2) inch shall be factory coated steel welded pipe and fittings or approved polyethylene pipe, and such steel pipe and risers for polyethylene pipe shall be cathodically protected. Field wrapping shall be limited to joints and fittings with polyethylene tape. Gas stops used in conjunction with service line piping shall be approved #175 tamper-proof type. All gas service lines with service line piping from the gas main to the gas meter two (2) inch and smaller shall be of approved Page 2 of 5 pages Agenda Item No. polyethylene pipe with approved anodeless risers and connectors. Plastic pipe and fittings shall conform to ASTM D2513-67 SDR-11. A #18 or larger insulated copper tracer wire shall be installed with all non-metallic gas piping and shall terminate above ground level at meter lo- cation, in no instance shall the wire be spiraled around the non-metallic pipe. Each service line must be properly supported on undisturbed soil or well compacted soil, and materials used for backfill must be free of :material that could damage the pipe or its coating. The minimum gas service line size shall be one and one-quarter (1 1/4) inch; provided, however, if gas pressure is in excess of five (5) pounds at the gas company main, the minimum size may be reduced to a minimum of three-quarter (3/4) inch with one (1) inch meter riser. All meter risers must be properly supported. " Section 2 . Section 1602 General Regulations; is amended by adding the following subsection: " (1602 . 2. 2) Underground gas piping; materials, sizes and installation. Underground gas piping from the gas meter to the building shall be either black steel pipe or polyethylene gas pressure pipe and fittings. Black steel pipe shall be protected against soil corrosion Page 3 of 5 pages Agenda Item No. -2- with an approved type coating. Coating shall extend six (6) inches above the finished grade. Couplings shall be the long recessed type coupling, plastic pipe and fittings shall conform to ASTM D2513-67 SDR-11, and of a minimum size of one and one-quarter (1 1/4) inch. Section 3. Subsection (1602 . 3) Welded joints; is hereby amended to read as follows: " (1602 . 3) Welded joints; steel pipe. Welding of gas pipe joints shall be performed by welders who are certified under Section IX of the 1974 edition of the ASME boiler and pressure vessel code; or Section 2 of the 1973 edition of the A.P. I. standard 1104. " Section 4. Section 1602. General Regulations; is amended by adding the following: " (1602 . 3. 1) jointing of polyethylene pipe. Jointing of polyethylene pipe shall be made by heat fusion or an approved non-corrosive com- pression type coupling with a non-removable internal stiffener. Heat fusion joints for polyethylene service lines from the gas main to the gas meter may only be made by persons who have been qualified under the procedure outlined in Section 192 . 285 of the Department of Transportation ' s "Regulations for Transmission of Natural and Other Gas by Pipeline" . Mechanical jointing materials shall be of the approved Page 4 of 5 pages -3- Agenda Item No. type and installed to comply with the manufacturer ' s recommendations. " Section 5. Ordinance declared an emergency measure and effective upon passage. Lone Star Gas Company which is governed by federal regulations concerning natural gas trans- mission lines requires that its customers' gas lines conform to those regulations as well; the installation of natural gas lines under the current plumbing code does not meet federal regulations and therefore causes additional expense to the public when changes are required by Lone Star Gas Company before it will accept the line for service. In order to avoid the confusion and added expenses occasioned by the nonconformance of the plumbing code with federal regulations this ordinance is declared to be an emergency measure which shall become effective upon its passage- PASSED AND APPROVED this A4liday of 1982 . �MAYOR ATTEST: --AL-4,,i-tie-/tA(1(W1-4- ----/ City Clerk Page 5 of 5 pages Agenda Item No. -4- Affidavit of Publication THE STATE OF TEXAS COUNTY OF WICHITA ORDINANCE NO. 1-82 AN ORDINANCE CLOSING re) AND ABANDONING GRACE. STREET BETWEEN 22ND STREET AND MCGREGOR On this day of ` STREET, AND RETAINING A UTILITY EASEMENT. ORDINANCE AMENDING A.D �,c3r;` personally appeared before me,the undersigned authority AN ORDINANCE AM THE PLUMBING CODE OF THE CITY OF WICHITA FALLS, TEXAS, PROVIDING 'l o:: ;.Ji. bookkeeper FOR THE MATERIALS,SIZES, INSTALLATION AND SUP- PORT USED IN CONSTRUCT- ING UNDERGROUND GAS for the Times Publishing Company of Wichita Falls, publishers of the Wichita Falls SERVICE LINES FROM THE GAS MAIN TO THE GAS 1 Record News, a newspaper published at Wichita Falls in Wichita County,Texas,and METER, PROVIDING FOR THE MATERIALS,SIZES AND INSTALLATION OF upon being duly sworn by me,on oath states that the attached,advertisement is a true UNDERGROUND GAS PIPING • FROM THE GAS METER TO THE BUILDING, REQUIRING and correct copy of advertising published in issues GAS PIPE WELDING BE PERFORMED ONLY By thereof on the following dates: CERTIFIED WELDERS, PROVIDING FOR THE METHODS OF JOINTING POLYETHYLENE PIPE AND DECLARING AMENDMENTS TO THE EMERGENCY 1,/ f MEASURES EFFECTIVE / UPON PASSAGE. /7-1 ORDINANCE NO.3-82 AN ORDINANCE APPROPRIATION M ROM THE Bookkeeper for Times Publishing Company GENERAL FUND TO of Wichita Falls ACCOUNT NUMBERS LISTED BELOW,AND DECLARING AN EMERGENCY. ORDINANCE NO.4-82 Subscribed and sworn to before me this the day and year first above written. AN ORDINANCE MAKING AN APPROPRIATION FROM THE GENERAL FUND TO ACCOUNT NUMBERS LISTED BELOW,AND DECLARING AN EMERGENCY. ORDINANCE NO.5-82 ORDINANCE REMOVING rsiy' Are$ ASSESSMENT AND LIENS FROM THE 1981 COMMUNITY DEVELOPMENT PAVING PROGRAM. tF0.Y P`B% ROY L.REAVES ORDINANCE NO.6-82 Notary Public,State of Texas / ORDINANCE WAIVING 5��-- ORDINANCES 3457, 3647, 3648, My Commission Expires Nov.30,19 AND 3699 AS TO ONE TRACT sr� `' $.$.446 42-2662 OF LAND. Of ORDINANCE NO. 7-82 AMENDING SECTION 15-127 OF THE CODE OF ORDINANCES OF THE CITY OF WICHITA FALLS,TO INCREASE THE NUMBER OF FIRE LIEUTENANTS BY ONE, AND DECREASE NUMBER OF FIRE CAPTAINS BY ONE. ORDINANCE NO. 8-82 AN ORDINANCE MAKING AN APPROPRIATION FROM THE WEST TEXAS UTILITIES FUND TO ACCOUNT NUMBERS LISTED BELOW, AND DECLARING AN IEMERGENCY.