Ord 068-93 6/15/1993 Ordinance No. 6r43
AN ORDINANCE AMENDING ORDINANCE 160-83 ADOPTING THE
STANDARD MECHANICAL CODE, 1991 EDITION, AS REVISED
IN 1992 & 1993, WITH CERTAIN AMENDMENTS AND
DELETIONS.
BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF WICHITA FALLS,
TEXAS, THAT:
SECTION 1. The publication entitled "Standard Mechanical Code",
1991 edition, as revised in 1992 & 1993, a copy of which, authenticated
by the signature of the City Clerk, is on file in the City Clerk's
office, is hereby adopted as the Wichita Falls Mechanical Code, as fully
as if copied at length herein and the "Standard Mechanical Code, " 1988
Edition, as revised in 1989, is hereby repealed in its entirety.
SECTION 2 . The following amendments and deletions are hereby made
in the "Standard Mechanical Code" as adopted herein:
(1) Section 105 is amended in its entirety to read as follows:
"105 Plumbing and Mechanical Board of Adjustments and Appeal Rules
and General Procedures.
Plumbing and Mechanical Board of Adjustments and Appeals.
105. 1 The Plumbing and Mechanical Board of Adjustments and Appeals
has been established by Ordinance No. 15-89 and same is hereby
incorporated in this Code as follows:
The Board shall consists of nine (9) members. Such Board shall be
composed of:
One (1) Master Plumber
One (1) Journeyman Plumber
Two (2) Air Conditioning Contractors
One (1) Mechanical Engineer
One (1) Mechanical Contractor
One (1) Lone Star Gas Company Representative
One (1) Representative from Home Building Industry
One (1) Member at large with no direct financial interest in the
construction industry
105.2 Of the members first appointed, five (5) shall be appointed
to serve until December 31, 1989, and four (4) shall be appointed to
serve until December 31, 1990. Thereafter, each member shall be
appointed to serve for a term of two years. Terms shall expire on
December 31, but each member shall continue to serve until his or her
successor is appointed. No member shall serve more than four (4)
consecutive terms.
105. 3 The Board Chairman and Co-Chairman shall be separately
selected by a majority vote of the Board. The Chairman and Co-Chairman
shall serve in such capacity for the duration of his/her term.
Page 2 of 30 Pages
Agenda Item No.
105.4 The Board is authorized to reverse or modify a refusal,
order, or disallowance of the Plumbing and Mechanical Inspector, or vary
the application of any provision of the Plumbing Code or Mechanical
Code, when properly appealed by any aggrieved party. Appeal to the
Board shall be allowed upon the following conditions:
1. Whenever the Plumbing and Mechanical Inspector shall
reject or refuse to approve the manner of installation proposed to be
followed or materials to be used,
2 . Or, when it is claimed that the provisions of the Plumbing
Code or Mechanical Code do not apply,
3 . Or, that an equally good or more desirable form of
construction can be employed in any specific case,
4. Or, when it is claimed that the true intent and meaning of
the Code or any of the regulations thereunder have been misconstrued or
wrongly interpreted.
5. Notice of appeal shall be upon forms as provided by the
Plumbing and Mechanical Inspector and such appeal shall be made within
thirty (30) days after the decision is rendered by the Plumbing and
Mechanical Inspector or his designee.
105. 5 Decisions of the Board.
105. 5. 1 A variance of the application of the Plumbing Code or
Mechanical Code may be granted by the Board when, in its opinion, the
enforcement thereof would do a manifest injustice, and would be contrary
to the spirit and purpose of the Plumbing Code or Mechanical Code or
public interest, or when in its opinion, the interpretation of the
Plumbing and Mechanical Inspector should be modified or reversed.
105.5.2 A decision of the Board to vary the application of any
provision of the Mechanical Code or Plumbing Code or to modify an order
of the Plumbing and Mechanical Inspector shall specify in what manner
such variation or modification is made, the conditions upon which it is
made and the reasons therefor. Every decision of the Board shall be
final, subject, however, to such remedy as an aggrieved party might have
at law or in equity. It shall be in writing and shall indicate the vote
upon decision.
105.5. 3 In addition to acting on appeals, the Board shall, from
time to time, as may be necessary, submit recommendations to the City
Council for adoption of new codes or ordinances.
105. 6 Quorum.
Five (5) members of the Board shall constitute a quorum. In
varying any application of the provisions of the Plumbing Code or the
Mechanical Code, or in modifying an order of the Plumbing and Mechanical
Inspector, affirmative votes of the majority present, but not less than
five (5) affirmative votes, shall be required.
Page 3 of30 Pages
Agenda Item No.
105.7 Conflict of interest.
A Board member shall not act in any case in which he or she has a
personal interest.
105.8 Absence of Board Members.
Continued absence of any member from regular meetings of the Board
shall, at the discretion of the City Council, render any such member
liable to immediate removal from office.
105.9 Records.
The Plumbing and Mechanical Inspector or his designee shall act as
secretary of the Board and shall make a detailed record for all Board
proceedings, which shall set forth the reasons for its decisions, the
vote of each member, and any failure of a member to vote. Such written
record, so taken in form of Board Minutes, shall be reviewed and
approved by the Board at the next regularly scheduled meeting. Such
approved minutes, along with any decisions of the Board, shall be
submitted to the City Council for acceptance.
105. 10 Procedure.
The Board shall establish rules and regulations for its own
procedure not inconsistent with the provisions of this Code. The Board
shall meet at regular intervals, to be determined by the Chairman, or in
any event, the Board shall meet within 10 days after notice of appeal
has been received. Every decision shall be promptly filed in writing in
the office of the Mechanical Official, and shall be open to public
inspection, a certified copy shall be sent by mail or otherwise to the
appellant and a copy shall be kept publicly posted in the office of the
Mechanical Official for 2 weeks after filing.
105. 11 Decisions.
The Plumbing and Mechanical Board of Adjustments and Appeals shall,
in every case, reach a decision without unreasonable or unnecessary
delay. If a decision of the Plumbing and Mechanical Board of
Adjustments and Appeals reverses or modifies a refusal, order, or
disallowance of the Mechanical Official, or varies the application of
any provision of this Code, the Mechanical Official shall immediately
take action in accordance with the decision.
(2) Section 107 is added which shall read as follows:
"107 Enforcement, Legal Procedure and Penalties.
It shall be the duty of the Building & Code Administrator to
enforce this ordinance. Any person, firm, corporation or agent who
violates, disobeys, omits, neglects or refuses to comply with or who
resists the enforcement of any of the provisions of this ordinance shall
be guilty of a misdemeanor offense punishable by a fine not to exceed
Five Hundred ($500. 00) Dollars. The imposition of one penalty for any
violation shall not excuse the violation nor permit it to continue, and
each day that the violation is maintained shall constitute a separate
Page 4 of 30 Pages
Agenda Item No.
offense. The application of such penalty shall not be held to prevent
the enforced removal of prohibited conditions. "
(3) Section 108 is hereby added which shall read as follows:
"108. Any person, firm, corporation or agent who shall construct,
enlarge, alter, repair, move, demolish, or change the occupancy of a
building or structure, or to erect, install, enlarge, alter, repair,
remove, convert or replace any electrical, gas, mechanical or plumbing
system, the installation of which is regulated by the technical codes,
or to cause any such work to be done, shall have an air conditioning
contractor license pursuant to Vernon's Annotated Civil Statutes, Art.
8861, and have a certificate of insurance must be on file with the City
Department.
Wichita Falls Inspection De
of p p
(4) Section 109 is added which shall read as follows:
"109 Insurance and Licensing Requirements.
(a) All persons, firms, corporations, or agents engaged in
the installation or repair of heating, ventilating, duct, air
conditioning and refrigeration systems for domestic or commercial
purposes in and about buildings where a person or persons live, work or
assemble in the City of Wichita Falls under terms of this Code shall,
before they do any work, execute and deliver to the City of Wichita
Falls a certificate of insurance showing the City of Wichita Falls as
certificate holder.
(b) Insurance shall be conditioned that all said heating,
ventilation, duct, air conditioning, and refrigeration systems shall be
done so that it conforms with all of the rules and regulations provided
by this Code. The insurance shall be further conditioned that the City
of Wichita Falls will be indemnified against all loss and damage
occasioned by the negligence of the principal therein failing properly
to execute and protect any work done by him or his employees or under
his direction or supervision.
(c) In case the principal on such insurance shall fail or
refuse to install or construct any heating, ventilating, duct, air
conditioning or refrigeration systems in accordance with such rules and
regulations contained in this Code, the owner of any house or premises
who may be aggrieved or injured thereby may have recourse on said
insurance, or the City may take action on the insurance for the use and
benefit of such owner, provided that in such case, such work is first
disapproved by the Mechanical Inspector as herein provided. Should the
Mechanical Inspector refuse to issue his certificate of approval of said
work on account of the failure of the mechanical installer to comply
with such rules and regulations, the Inspector shall notify the
principal to make such changes as are required to comply with the rules
and regulation; in case of failure or refusal on the part of said
principal to rectify or change such work so as to make it comply with
such rules and regulations, then after three (3) days from the time
notice was given it shall be the duty of the sureties on the insurance
herein required to make the required changes; in default of the
principal or the sureties on the insurance performing the same as herein
provided, the said owner, or the City for the owner's benefit, may have
Page 5 of 30 Pages
Agenda Item No.
L
recourse against the principal and sureties on the insurance herein
provided for.
(d) Said insurance shall run the calendar year and be renewed
on January 1, and no heating, ventilating, duct, air conditioning and
refrigeration systems shall be done by, and no permits issued to, any
contractor unless he has such insurance in full force and effect.
(e) An person required to have an air conditioning contractor
license pursuant to Vernon's Annotated Civil Statutes, Art. 8861, shall
file a copy of his license with the City Inspection Department and shall
also file a copy of any renewal license not later than thirty (30) days
after the renewal license is obtained. "
(5) Subsection 303 .4. 1. shall be amended to read as follows:
"303 .4 . 1 Every attic or furred space in which mechanical equipment
is installed shall be accessible by an opening and passageway as large
as the largest piece of equipment and in no case less than twenty-two
(22) by thirty-six (36) inches continuous from the opening to the
equipment and its controls. Every passageway shall be unobstructed and
shall have solid continuous flooring not less than twenty-four (24)
inches wide from the entrance opening to the equipment. On the Control
side and on other sides where access is necessary for servicing the
equipment, a level working platform extended a minimum of thirty (30)
inches from the edge of the equipment with thirty-six (36) inch high
clear working space shall be provided. Top or bottom service equipment
shall have a full clearance above or below the unit for component
removal.
(6) Subsection 303 . 6.2 is hereby amended to read as follows:
"303 .6.2 Every appliance located on the roof of a building shall
be installed on a substantial level platform. Whenever the roof has a
slope greater than three (3) to twelve (12) , a level working platform
not less than thirty (30) inches deep shall be provided in front of the
entire fire box and control sides of the appliance. All sides of the
working platform facing any portion of the roof edge below the platform
where Code required shall be protected by substantial railing forty-two
(42) inches high with vertical rails not more than twenty-one (21)
inches apart, except that parapets at least twenty-four (24) inches high
may be utilized in lieu of rails or guards. Required working platforms
and railings may be omitted when access to the equipment is through a
required roof scuttle and all of the following provisions are met:
(1) The required scuttle is located immediately adjacent to
the control side of the equipment unit.
(2) All controls, filters, burners, fans and motors are
accessible for service and repair within two (2) feet of the edge of the
equipment platform on the scuttle side.
(3) The equipment platform is not more than twenty (20)
inches above the high side of the scuttle opening.
Page 6 of 30 Pages
Agenda Item No.
(4) A substantial working platform not less than thirty (30)
inches by thirty (30) inches shall be provided directly below the
scuttle at a point not less than thirty (30) inches nor more than
thirty-two (32) inches below the high side of the scuttle opening.
(5) Scuttles located on other than the roof incline side of
the equipment unit shall have their lids or trapdoors hinged on the low
side of the scuttle. "
(7) Subsection 305. 3 .5 is hereby deleted in its entirety.
(8) Subsection 305. 3 .6 is hereby deleted in its entirety.
(9) Section 308 is amended by the addition of Subsection 308. 6.6. 1
to read as follows:
"308. 6. 6. 1 Fire extinguishing equipment, as required by 308.7, may
be omitted from hoods and duct systems on fully enclosed ovens (e.g.
pizza oven, convection ovens) if the manufacturer's listing approves
such installation. All other installation parameters shall be the same
as specified in 308.4. "
(10) Section 308 is hereby amended by the addition of Subsection
308. 6. 6.2 to read as follows:
"308. 6. 6.2 Exhaust hoods and duct systems, other than those
constructed as per 308.4 and 308. 6, if requested by the owner may be
installed over the following equipment only:
1) Dishwashers
2) Steam Tables
3) Other heat producing items that do not require a Hood
pursuant to Subsection 308.6.
Such load construction shall be of not less than 24 gauge steel.
Connecting duct shall be of not less than 26 gauge or SMACNA standard,
whichever is larger. "
(11) Subsection 506. 1.4 is hereby amended to read as follows:
"506. 1.4. 1.4 Linin g shall be interrupted for a minimum of eighteen
(18) inches upstream and thirty (30) inches downstream from electric
resistance or fuel burning heaters and a duct system unless the heater
is specifically listed for installation with zero (0) clearance within a
lined duct. "
(12) Subsection 506.2. 1 is hereby amended to read as follows:
"All metal supply duct work installed in unconditioned spaces shall
be insulated. All metal duct installed in spaces having dewpoint
temperatures lower than the duct shall be insulated. Insulation shall
be a minimum of one and one-half (1-1/2) inches thick, three-quarter
(3/4) pound density blanket or one (1) inch thick, one and one-half (1-
Page 7 of 30 Pages
Agenda Item No.
1/2) pound density liner. Insulation shall have maximum thermal
conductance (Btu/hr-Pt2-?F) when tested in accordance with ASTM C518 of
0.25. When ducts handling cool air are externally insulated, the
insulation shall be covered with a vapor barrier having a maximum
permeance of 0.5. perms or aluminum foil having a minimum thickness of
two (2) mils. When nonmetal ducts or other approved insulating or
lining materials are used, the maximum thermal conductance value of the
material shall be 0.25 at 752F. All exterior ducts insulated shall be
properly protected with an approved weatherproof vapor barrier. "
(13) Subsection 506.2 .2 is hereby amended to read as follows:
"Where duct line installed to satisfy the requirements of 506.2. 1
has been interrupted, a duct covering of equal thermal performance shall
be installed. "
(14) Subsection 604. 1 is amended in its entirety to read as
follows:
"604 . 1 All chilled water piping and fittings shall be of steel,
copper, brass or polyvinyl chloride plastic (PVC) Schedule 40 type I and
II high and normal impact, PVC Schedule 80 type I and II high and normal
impact. Pressure rated cement-asbestos epoxy lined pipe may be used
where temperature of water does not exceed 210?F. The aforementioned
materials shall be installed in compliance with Table 604. "
(16) Section 608.4 is hereby deleted in its entirety.
(17) Table 610 is hereby amended in its entirety to read as
follows:
"TABLE 610
MINIMUM PIPE INSULATION
Insulation Thickness in Inches
For Pipe Sizes 2
Fluid
Piping Temper- Run- 1" 1-1/4" 2-1/2" 5"
System ature Outs And To To And
Types Range,kF 2" - Less 2" 4" Larger
Heating System
Steam & Hot water
High pressure/temp 306-450 1-1/2 2-1/2 2/12 3 3-1/2
Med. pressure/temp 251-305 1-1/2 2 2-1/2 2-1/2 3
Low pressure/temp 201-250 1 1-1/2 1-1/2 2 2
Low temperature 120-200 1/2 1 1 1-1/2 1-1/2
Steam condensate Any 1 1 1-1/2 2 2
(for feed water)
Cooling Systems
Chilled water, 40-55 3/8 3/8 3/4 1 1
refrigerant, or
brine below 40 1 1 1/2 1-1/2 1-1/2
Page 8 of 30 Pages
Agenda Item No.
1. Runouts not exceeding 12 ft. in length to individual terminal units.
2. For piping exposed to outdoor air, increase thickness by 1/2 inch. "
(18) Subsection 801.2 is hereby amended in its entirety to read as
follows:
"801.2 Underground Leads.
A disconnecting means shall be installed within sight and easy
reach in the ungrounded leads of each power circuit to electrically
operated components. The disconnecting means shall in no case be
installed farther than six (6) feet from the service side of the
equipment. "
(19) Appendix A is adopted.
SECTION 3 . All specifications and requirements regarding
polybutylene pipe are hereby deleted in their entirety.
PASSED AND APPROVED THIS THE WDAY O X-t\-Jc.2 1993
M A Y O R
ATTEST:
.1-
/
CITY CLERK "
Page 9 of30 Pages
Agenda Item No.
Ad 523399
• Affidavit of Publication
ORDINANCE NO.65-93
ORDINANCE CLOSING HEAR- ° THE STATE OF TEXAS
ING AND FINDING CERTAIN
BUILDINGS AND/OR STRUC- COUNTY OF WICHITA
TURES TO BE DANGEROUS:
COMMANDING PROPERTY
OWNERS TO REPAIR OR DE- Here)
MOLISH SAID BUILDINGS
AND/OR STRUCTURES WITHIN 9 t h J U I Y
day Of.
THIRTY(30)DAYS OF THE DATE On this fl Y
OF THIS ORDINANCES AND
DECLARING AN EMERGENCY 1993
ORDINANCE NO.66-93
ORDINANCE WAIVING APPEN- A,D, personally appeared before me, the undersigned authority
DIX A,SUBDIVISIONS SECTION
9(B) (2)(a)OF THE CODE OF D a C 1 C e Ming bookkeeper
ORDINANCES WITH RESPECT TO
PLACING CURB AND GUTTER
ON THE EAST SIDE OF FM1634, for the Times Publishing Company of Wichita Falls, publishers of the Wichita Falls
ADJACENT TO THE WEST LINE
OF LOT 13, UNIT 34, WICHITA VALLEY FARMS Times/Record News, a newspaper published at Wichita Falls in Wichita County,
ORDINANCE NO.67-93
ORDINANCE WAIVING SEC- Texas, and upon being duly sworn by me, on oath states that the attached
TION 47-49 OF THE CODE OF
ORDINANCES WITH RESPECT TO advertisement is a true and correct copy of advertising published
PLACING A SIDEWALK ALONG
THE WEST UNE OF LOT 13,UNIT in one (1) issues thereof on the following dates:
34,WICHITA VALLEY FARMS
ORDINANCE NO.68-93
AN ORDINANCE AMENDING U I Y 5 s 1993
ORDINANCE 160-83 ADOPTING J
THE STANDARD MECHANICAL
CODE, 1991 EDITION, AS RE- ..
VISED IN 1992 & 1993, WITH ,1SL �. ...) ei
CERTAIN AMENDMENTS AND vy,
DELETIONS. �J
ORDINANCE ORDINANCE O.69.93 Bookkeeper for Times Publishing Company
AN ORDINANCE AMENDING
APPENDIX B,ARTICLE II,PLUMB of Wichita Falls
ING CODE, OF THE CODE OF
ORDINANCES OF THE CITY OF
WICHITA FALLS;ADOPTING THE
STANDARD GAS CODE, 1991 •
EDITION,AS REVISED IN 1992& >EAL) Subscribed and sworn to before me this the day and year first above written.
1993 WITH CERTAIN AMEND-
MENTS AND DELETIONS
ORDINANCE NO.70-93
AN ORDINANCE AMENDING /(/ ,J. �,
APPENDIX B,ARTICLE I,PLUMB- % . 1 /
ING CODE, OF THE CODE OF � � � t,
ORDINANCES OF THE CITY OF rem,
WICHITA FALLS;ADOPTING THE ,F,X,,,.. , ��
STANDARD PLUMBING CODE, s•°'"°-:,3. p
1991 EDITION, AS REVISED IN a E Or ,,,,',,i� ;,;;;,
1992-1993, WITH REVISED „E x. ;,i. - `-"31'.
AMENDMENTS AND DELETIONS. s w�-°.».` 5'
ORDINANCE NO.71-93 s.4•r••s,.-'
ORDINANCE WAIVING APPEN-
DIX A,SUBDIVISIONS SECTION ORDINANCE NO.75-93
9(B)(2) (a)OF THE CODE OF AN ORDINANCE OF THE CITY
ORDINANCES WITH RESPECT TO COUNCIL OF THE CITY OF
PLACING CURB AND GUTTER WICHITA FALLS AMENDING
ON THE EAST SIDE OF HUNT- SECTION 29-44 OF THE CODE
WEST LINE, ADJACENT TO THE OF ORDINANCES OF THE CITY
WEST UNE OF LOT 1,BLOCK 1, OF WICHITA FALLS TO ALLOW U-
MOORE SUBDIVISION,WICHITA TURNS UNLESS PROHIBITED;
COUNTY,TEXAS REPLEALING ALL ORDINANCES
ORDINANCE NO.72-93 OR PARTS OF ORDINANCES IN
ORDINANCE WAIVING APPEN- CONFLICT HEREWITH; PROVID-
DIX A, SUBDIVISIONS SECTION ING A SAVINGS CLAUSE;FIND-
9(B)(2)(a)OF THE CODE OR ING AND DETERMINING THAT
ORDINANCES WITH RESPECT TO
PLACING CURB AND GUTTER THE MEETING AT WHICH THIS ON THE EAST SIDE OF HUNT- ORDINANCE WAS PASSED WAS
INGTON LANE, ADJACENT TO OPEN TO THE PUBLIC AS RE-
OUIRED BY LAW; PROVIDING
THE WEST UNE OF LOT 1,BLOCK FOR PUBLICATION; AND
1, WEST JOHN THOMAS AD- PROVIDING FOR AN EFFECTIVE
DITION DATE.
ORDINANCE NO.73-93 ORDINANCE NO.76-93 •
ORDINANCE WAIVING SEC- AN ORDINANCE OF THE CITY
TION 27-29 OF THE CODE OF IL OF THE CITY OF
ORDINANCES WITH RESPECT TO COUNCIL FALLS AMENDING OR-
PLACING A SIDEWALK ALONG DINANCE NO.21-93 TO DELETE BLOCK 72,FAITH VILLAGE,UNIT FROM SUCH ORDINANCE THE STRUCTURES LOCATED AT 1111
11
ORDINANCE 74-93 1AYLOR, LOT 10, BLOCK 37,ORDINANCE WAIVING APPEN- FLORAL HEIGHTS ADDITION;FINDING AND DETERMINING
DIX A SUBDIVISIONS SECTION THAT THE MEETING AT WHICH
9(B)(2)(a)OF THE CODE OF THIS ORDINANCE WAS PASSED
ORDINANCES WITH RESPECT TO WAS OPEN TO THE PUBUC AS
PLACING CURB AND GUTTER REQUIRED BY LAW.
ON THE WEST SIDE OF WELL-
INGTON LANE, ADJACENT TO
THE EAST UNE OF LOT 2,BLOCK �r 5'1,WESTRIDGE ESTATES
ORDINANCE NO.75-93
AN ORDINANCE OF THE CITY
COUNCIL OF THE CITY OF •
WICHITA FALLS AMENDING
SECTION 29-44 Of THE CODE
OF ORDINANCES OF THE CITY
.- �...��w•III�W 11_ .