Loading...
Ord 132-94 10/4/1994 ORDINANCE NO. 1a-G AN ORDINANCE AMENDING CHAPTER 14, OF THE CODE OF ORDINANCES OF THE CITY OF WICHITA FALLS, CITY ELECTRICAL CODE. WHEREAS, it is the desire of the City to adopt and maintain an Electrical Code for the protection and safety of its citizens, and, WHEREAS, members of the Inspection Division and the Board of Electrical Examiners have reviewed and have voiced approval for the amendments as contained herein, NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF WICHITA FALLS, TEXAS, THAT: Section 14-16 (A) (2) shall be amended to read as follows; " (2) In case of applicant's request for re-examination, the applicant may apply for re-examination immediately, and in accordance with the provisions of this ordinance shall be scheduled by the Electrical Inspector to take the next regularly scheduled examination set by the Board. " Section 14-16, (A) (3) and (A) (4) are hereby deleted. Section 14-25 shall be amended to read as follows; "Sec. 14-25. Identification Cards Electrical Inspectors shall have in their possession, proper employee identification at all times when engaged in the enforcement of this Code. " Section 14-36 (B) , shall be amended by adding paragraphs (5) , (6) and (7) to read as follows: " (5) An electrical contractor license shall expire on the thirty- first day of December and may be renewed thereafter. (6) Effective January 1, 1995 a fee shall be charged for each electrical contractor license, issued in accordance with the fee schedule in Section 14-77 and 14-78 of this code. (7) No permits shall be issued to any Master Electrician whose contractors license is not current. " Section 14-45, (2) and (3) shall be amended read as follows; " (2) The applicant shall have 5 years experience at the apprentice level in electrical construction as determined by the Board, or (3) The applicant shall hold a vocational school degree in electrical construction from a school with a full time two year program and have three (3) years of full time experience in electrical construction, as determined by the Board, or" Section 14-46, (1) and (2) shall be amended to read as follows; " (1) Meet all requirements of Sec. 14-44 for a Master Electricians license. (2) Shall be a full time employee of a company or business within the City of Wichita Falls. " Section 14-46, (3) and (4) are hereby deleted. Section 14-63 , (A) and (B) shall be amended to read as follows; " (A) Each vehicle used in the business of electrical contracting work in the city shall be properly identified by the placement of a sign or lettering on such vehicle. The sign shall display the name of the person, corporation, or company doing business and the lettering for such sign shall be at least two (2) inches in height in contrasting colors. These signs shall be placed on both front doors of each vehicle or on both upper side panels of vans. (B) In addition, all trucks or other vehicles used by any master electrician shall also have, placed upon the left hand side of such vehicle, the license number of the master electrician, in numbers a minimum height of two (2) inches in size. These numbers shall be placed above the door signs or included as part of the sign. " Section 14-73 , (B) (4) is amended to read as follows: " (4) the type of inspection requested shall be: E1 (Construction tap) or E2 (Rough in - before work is covered) or E3 (Final - All work complete, power on) or E4 (Re-inspection - when work is rejected) or E5 (Courtesy inspection - to discuss or plan work) or E6 (Electrical system safety check - before power is connected or occupancy change to existing service) or E9 (Temporary power on - to power system before final inspection. If the structure is occupied or code violations are noted, the electrical inspector may request immediate disconnect of service to the Electrical Utility) " Section 14-77 is amended to read as follows: "Sec. 14-77 . License Fee The following fees are hereby established and shall be charged and assessed to every applicant for any class of license authorized by this Code who has successfully completed the examination for such license and such fees shall be charged to every licensed electrician who has failed to renew his license as provided for in Sec. 14-62 (F) of this Code: (1) Electrical contractor license fee $300.00 (2) Master electrician license fee $100. 00 (3) Industrial electrician license fee $100. 00 (4) Journeyman electrician license fee $ 25. 00 (5) Maintenance electrician license fee $ 20.00" Section 14-78 is amended to read as follows; "Sec. 14-78 . Renewal License Fee The following fees are hereby established and shall be charged and assessed for the renewal of any class of license authorized by this Code when such license authorized by this Code when such license is renewed in accordance with the provisions of Sec. 14-62 of this Code: (1) Electrical contractor license renewal fee $300. 00 (2) Master electrician license renewal fee $ 50. 00 (3) Industrial electrician license renewal fee $ 50. 00 (4) Journeyman electrician license renewal fee $ 20. 00 (5) Maintenance electrician license renewal fee $ 10. 00" Section 14-83 , paragraph one shall be amended to read as follows; "All wiring shall be installed in rigid metallic conduit, electrical metallic tubing, approved metallic raceways, approved metal clad cable, approved nonmetallic conduit and raceway or approved multi-outlet assemblies. However; all single-family and multifamily residences not exceeding three (3) stories and out-buildings on the same premises may be wired in nonmetallic sheathed cable as a minimum requirement. However, if any part of a residence or other building is converted to any commercial purposes not within the above exceptions, the entire building shall be classified as a business premises and the entire building shall be rewired. All conduit installed for electrical use shall be installed under the requirements of this chapter. " Section 14-83 , (1) , (2) , (3) and (4) shall be amended to read, as follows; " (1) Electrical Non-metallic Tubing (ENT) shall not be used in any location except where NM cable is acceptable in the City of Wichita Falls. (2) Manufactured wiring systems as approved by N.E.C. shall be acceptable. (3) No electrical metallic tubing (EMT) shall be permitted in any electrical installation where such tubing is in contact with the ground or earth or is embedded in a concrete slab. (4) All MC cable shall have a green grounding conductor. " Section 14-84 (A) . Shall be deleted in its entirety. Section 14-85, (A) shall be amended to read as follows; " (A) A conduit of not less than three-fourths (3/4) inch trade size shall be installed from the panel to an accessible crawl space in the attic, under the floor or to the outside of the house if it has no attic and has a concrete floor. This conduit is to facilitate the future installation of the two (2) space circuits to be left open as spares in all residential panels. " Section 14-85, (C) and (D) are hereby deleted. Section 14-86. Shall be amended to read as follows; "Sec. 14-86. Commercial circuits shall be installed as required by the currently adopted addition of the National Electrical Code. " Section 14-87. (A) , (C) , (D) & (I) shall be amended to read as follows; "Sec. 14-87. Service Entrance " (A) All Metal Entrances - An all metal complete service entrance shall be used from the point of contact with the Electric Company to the service switch or distribution panel except as provided in this Chapter. Underground service entrance may be schedule 40 PVC, (C) Overhead Service Drop Provisions: (1) All New Installations - When a new Electrical Installation is to be served with an overhead service drop, a means of attachment shall be provided. When an Electrical Installation is started before the Electric Company shall be the responsibility of the facilities are placed, it h P Y Electric Company to determine the location of the facility from which the service drop for the Electrical Installation will be installed. The means of attachment shall be a clamp on a service mast or a galvanized "hook" bolt or "eye" bolt, rigidly attached to rafter or stud to give adequate support to the service drop. Landing and meter heights shall comply with the utility company guidelines. (2) Additions to Existing Installations - When an addition is to be made to an existing building that requires that the service entrance be relocated to the new portion of the building, the service entrance shall comply with the rules established for all new installations. (3) Existing Installations - When the meter loop is changed on an existing installation, the installation shall reasonably comply with the National Electrical Code and Section 14-87 of this Chapter without altering the roof of the existing building. The means of attachment shall be changed by the Master Electrician or the Homeowner and shall be at the maximum height that can be maintained on the building. The new means of attachment shall be an "eye" bolt or "hook" bolt, rigidly attached to rafter or stud and to give adequate support to the service drop. Other suitable means of attachment, including insulators attached with a single lag screw, may be approved by the Electrical Inspector if commonly accepted within the trade. (D) Service Mast - In the event a service mast is used to attain the height required by the National Electrical Code, the service mast shall be a minimum two-inch (2") IMC or (rigid conduit) having adequate strength to withstand the strain of the service drop and shall meet minimum standards established by the Electric Company and approved by the Board as defined in the publication, "National Electric Safety Code, " from the Electric Company. (I) Minimum Conductor Use - The service entrance shall conform to the National Electrical Code, except that the entrance conductor size shall not be less than the equivalent of Number 6 THW copper. " Section 14-88 . (A) and (B) are amended to read as follows; " (A) Conductors - Conductors and cables on underground service entrances may be installed in approved raceways or may be buried direct in the earth when approved direct burial cables are used. 1 . 4 • (B) Mechanical Protection - Rigid metal raceways or electrical metallic tubing shall be used on underground service entrance conductors to provide mechanical protection where needed. Raceways approved for the purpose shall be provided for underground service entrance conductors entering under projection of a building such as, but not limited to, porches, patios, concrete driveways, walkways or pads adjacent to a building which does not provide adequate space between driveways, walkways or pads in order to permit repair of replacement of conductors, and the raceway shall be continuous from the point of entry under any projections to the service entrance switch or panel. " Section 14-89 . Is amended to read as follows; "Sec. 14-89 . Underground Feeder Circuits and Branch Circuits Feeder circuits and branch circuits installed underground shall comply with the full requirements of Sec. 14-88 of this Chapter for underground service entrances. " Section 14-91. is amended by deleting the last paragraph, noted as "exception" . Section 14-93 . is hereby deleted. Sec. 14-100. (B) , (C) & (D) shall be amended to read, as follows; " (B) All low voltage transformers, such as may be used for door bells, floor furnaces and other such installations, shall be installed in a convenient and readily accessible place. (C) All wiring, line voltage or low voltage used for data processing or energy control and like systems shall be considered electrical work and must conform to this Code. (D) All other wiring shall conform to National Electrical Code. " PASSED AND APPROVED this the •ay of 011 !_ 1994 . ' MAYOR ATTESTED: 4 1 I ) CI Y CL RK Ad 591026 • Affidavit of Publication ORDINANCE NO.130-94 THE STATE OF TEXAS ORDINANCE CLOSING HEAR- ING AND FINDING CERTAIN COUNTY OF WICHITA BUILDINGS AND/OR STRUC- TURES TO BE DANGEROUS: (p' COMMANDING PROPERTY OWNERS TO E To) SAID ' BUILDINGS AND/OR STRUC- 20th O c t o b e r TURES WITHIN THIRTY (30) On this day of DAYS OF THE DATE OF THIS ORDINANCE AND DECLAR- ING AND EMERGENCY. 1994 ORDINANCE NO.131-94 A.D. personally appeared before me, the undersigned authority ORDINANCE ACCEPTING FUNDS FROM IE FOR bookkeeper THE TEXAS Karen Cobb FOREST SERVICE TREE GRANT AND AP- PROPRIATING FUNDS IN for the Times Publishing Company of Wichita Falls, publishers of the Wichita Falls THE GENERAL FUND TO AC- COUNT FOR EXPENSES RE- Times/Record News, a newspaper published at Wichita Falls in Wichita County, LATED TO THIS GRANT ORDINANCE NO.132.94 ORDINANCE AMENDING Texas, and upon being duly sworn by me, on oath states that the attached CHAPTER 14, OF THE CODE OF ORDINANCES OF THE advertisement is a true and correct copy of advertising published CITY OF WICHITA FALLS, CITY ELECTRICAL CODE. in 1 Cone ) issues thereof on the following dates: ORDINANCE NO.133-94 AN ORDINANCE ZONING LOTS 1-22B, BLOCK 2, NOB October 201 19 9 4 HILL SUBDIVISION,WICHITA FALLS, TEXAS, TO A PLANNED UNIT DEVELOP- MENT(PUD 94-07)";FINDING AND DETERMINING THAT THE MEETING AT WHICH THIS ORDINANCE WAS Bookkeeper for Times Publishing Company WAS OPEN TO THE p g om any p PUBLIC AS REQUIRED BY :•LAW. °y ;� of Wichita Falls ORDINANCE NO.134-94 ORDINANCE GRANTING A }; WAIVER TO AGAPE FELLOW: L Subscribed and sworn to before me this the day and year first above written: t"ti SHIP CHURCH OF SECTION 4600 OF THE ZONING ORDI- NANCE REQUIRINGSENTIAL ,1 t SCREEN- ING OF NONRESIDENTIAL /�}"'/ - USES ADJACENT TO SINGLE- FAMILY USES;FINDING AND DETERMING THAT THE MEETING AT WHICH THIS ORDINANCE WAS PASSED WAS OPEN TO THE PUBLIC AS REQUIRED BY LAW. ORDINANCE NO.135-94 ORDINANCE WAIVING AP- PENDIX A, SUBDIVISION SECTION 9(B)(2)(a)OF THE CODE OF ORDINANCES WITH RESPEFT TO PLACING CURB AND GUTTER ON THE WEST SIDE OF HORSESHOE LAKE ROAD, ADJACENT TO THE EAST LINE OF LOT 1,UNIT59, WICHITA VALLEY FARMS. ORDINANCE NO.136-94 ORDINANCE WAIVING AP- PENDIX A, SUBDIVISION SECTION 9(B)(2)(a)OF THE CODE OF ORDINANCES WITH RESPECT TO PLACING CURB AND GUTTER ON THE SOUTH SIDE OF ANCHOR ROAD,AD- JACENT TO THE NORTH LINE OF LOT 1,BLOCK 1,DAVID M. COOK ADDITION